Tomorrowish

GHG conversion factors 2025 and 2026: how to use them

Every UK Carbon Reduction Plan turns activity (kWh, litres, miles, tonnes) into tonnes of CO2e with the UK Government's GHG conversion factors for company reporting, published by DESNZ (with DEFRA) every June. Here's what you need to know to use them, or to check a plan that did.

The files

SetPublishedFiles
202611 June 2026; flat file revised 31 July 2026Full set, flat file. No condensed set this year.
202510 June 2025Condensed set (for most users), full set, flat file
20248 July 2024 (v1.1 October 2024)Condensed set, full set, flat file

The 2026 flat file was re-issued on 31 July 2026 to correct a number of values that were initially reported as 0. If you downloaded it in June or early July 2026, download it again.

The flat file has one row per factor with columns Scope, Level 1 to 4, Column Text, UOM, GHG/Unit and the factor. For a Carbon Reduction Plan you want the rows where GHG/Unit is kg CO2e, which already combine the seven Kyoto gases.

Which year's set to use

Use the set for the year you are reporting on: 2025 activity with the 2025 set, 2023 activity with the 2023 set. For a financial year, the usual choice is the set for the calendar year it ends in; say which you used. Don't re-calculate an old baseline with this year's factors unless you say so, because the factors move.

Why your electricity figure drops this year

UK grid electricity (Scope 2), kg CO2e per kWh2023202420252026
Electricity: UK, location-based0.207070.207050.177000.13096

The same kWh produce 26% less Scope 2 with the 2026 factor than with the 2025 one, because the UK grid itself emitted less per kWh in the data behind the new set. That's a change in the grid, not in your business. A good plan says so rather than claiming it as its own saving.

The rows a small business usually needs (2026 set)

WhatFlat file pathkg CO2e per unit
Gas from billsFuels › Gaseous fuels › Natural gas › kWh (Gross CV)0.18231 per kWh
Grid electricityUK electricity › Electricity generated › Electricity: UK › kWh0.13096 per kWh
Diesel from a fuel cardFuels › Liquid fuels › Diesel (average biofuel blend) › litres2.58354 per litre
Heating oilFuels › Liquid fuels › Burning oil › litres2.54016 per litre
Average van, dieselDelivery vehicles › Vans › Average (up to 3.5 tonnes) › Diesel › miles0.41386 per mile
Average car, fuel not known (mileage claims)Business travel- land › Cars (by size) › Average car › Unknown › miles0.26699 per mile
National railBusiness travel- land › Rail › National rail › passenger.km0.03092 per passenger-km
Short-haul flight, economy, with radiative forcingBusiness travel- air › Flights › Short-haul, to/from UK › Economy class › With RF0.12576 per passenger-km
UK hotel nightHotel stay › UK › Room per night10.4 per night

Two traps: gas bills show kWh already on a gross calorific value basis, so use the Gross CV row (not Net CV); and for flights DESNZ recommends including radiative forcing (the "With RF" rows) to capture the full climate effect.

Or let the builder do it

The builder carries every DESNZ set from 2019 to 2026, converted from the official flat files, and picks the set that matches each year. Each line shows the factor and its row number in the flat file, and the plan's annex lists them all, so the arithmetic can be checked against the spreadsheet. When DESNZ publishes the 2027 set next June, it will be added.

Factors from the UK Government GHG Conversion Factors for Company Reporting (DESNZ). Contains public sector information licensed under the Open Government Licence v3.0.

Not affiliated with the Cabinet Office, the Government Commercial Agency, NHS England or DESNZ. Quotes from PPN 006, its template and NHS England guidance are Crown copyright and reused under the Open Government Licence v3.0. Checked against the sources on 2026-10-24.